中频炉为何总是烧穿同一个晶闸管?
在水路畅通、散热器与晶闸管(晶闸管)的安装符合标准的前提下,总是烧穿同一个晶闸管
检查如下:
1. 与该晶闸管对应的阻容吸收电路是否开路(电阻或电容内部断路)?
2. 检查对应于该晶闸管的脉冲功放板,上面的电阻、电容及二极管,包括脉冲变压器自身是否完好?
3. 特别要注意:脉冲变压器发光二极管亮不能判定脉冲变压器是否完好。需要更换新的脉冲变压器替换。
4. 检查晶闸管触发线对应的输出端子是否松动。
https://songdaokeji.cn/
Why does the induction melting furnace always burn through the same thyristor?
Under the premise that the waterway is unblocked and the installation of the radiator and thyristor (thyristor) meets the standard, the same thyristor will always be burnt through
Check as follows:
1. Is the resistance-capacitance absorption circuit corresponding to the thyristor open (the resistor or capacitor is internally open)?
2. Check the pulse power amplifier board corresponding to the thyristor. Are the resistors, capacitors and diodes on it, including the pulse transformer itself intact?
3. Pay special attention: the light-emitting diode of the pulse transformer cannot determine whether the pulse transformer is intact. Need to replace with a new pulse transformer.
4. Check whether the output terminal corresponding to the trigger line of the thyristor is loose.